RFM0.375-300-1S37510003004*84.93361533702M12292
RFM0.375-500-1S37510005006*94.44401704203M12423
RFM0.375-600-1S37510006006*113.24401704803M12534
RFM0.375-250-2.5S37525002504*28.3361232201M12145
RFM0.375-500-2.5S37525005004*56.63361233701M12246
RFM0.375-750-2.5S37525007506*56.63361533702M12247
RFM0.375-850-2.5S37525008506*64.23361534202M12328
RFM0.375-1000-2.5S375250010006*75.53361704502M16399
RFM0.375-260-4S37540002604*18.43361232201M121410
RFM0.375-360-4S37540003604*25.53361232201M121411
RFM0.375-720-4S37540007204*513361233701M162412
RFM0.375-320-8S37580003204*11.33361232201M121413
RFM0.375-500-1S37580008004*28.33361233701M162414
RFM0.5-500-1S50010005006*53.13361533702M122915
RFM0.5-1070-1S500100010708*85.24401704804M125416
RFM05-250-2.5S50025002504*15.93361232201M121417
RFM0.5-500-2.5S50025005004*31.83361233201M122418
RFM0.55-1000-2.5S550250010006*35.13361533702M122919
RFM0.75-750-0.5S7505007506*70.83361535002M124120
RFM0.75-1000-0.5S750500100010*56.64401704805M125521
RFM0.75-360-1S75010003604*25.53361232201M121422
RFM0.75-720-1S75010007204*513361233701M1224
1.电容器的连续运行电压为1.00Un,且能在如下表所规定的稳态过电压下运行相应的时间。
2.能为电容器所耐受而不受到显著损伤的过电压值取决于持续时间、总的次数和电容器的温度。
3.高于1.15Un的过电压是以在电容器的寿命期间发生总共不超过200次为前提确定的。
允许在由于过电压和高次谐波造成的有效值为额定电流的1.30倍的稳态过电流下运行。对于电容具有最大正偏差的电容器,稳态过电流允许达到额定电流的1.43倍。
4.电容偏差为:-5%~ 10%。
5.损耗角正切值tarδ(在额定电压下,20℃时)a.采用膜纸复合介质的产品不大于0.0012。b.采用全膜介质的产品不大于0.0005(不含内熔丝)。c.带内熔丝的电容器损耗角正切值、在定货时协商确定。
6.电容器分户内型和户外型,并有适合于湿热地区,高原地区及污秽地区等各种特殊环境用的产品。
7.产品技术性能符合GB3983-89、GB/T11024-2001《高低压并联电容器》国家标准及lEC871-1(1987)要求。
高电压并联电容器主要应用于50HZ或60HZ交流电力系统以改善功率因数,产品性能负荷GB3983.2-89《高电压并联电容器》及国际标准IE60671-1.
高压并联电容器价格255元,电容器 用字母C表示。 顾名思义,是‘装电的容器’,是一种容纳电荷的器件。 电容器是电子设备中大量使...
电容串联时,通高虑低,低频的信号不容易通过电容,高频的很容易通过。高音喇叭不需要低音信号,所以串联。这样做的好处就是,减小攻防的低频负载,同时使高音喇叭免除低音信号影响,高音更纯。 电容并联时可以滤除...
两者的区别:并联电容器组的等效电容等于电容器组中各电容之和,而串联电容器组等效电容的倒数等于电容器组中各电容倒数之和。串联电容器组的等效电容比电容器组中任何一个电容器的电容都要小,而串联电容器组的等效...
1.电容器主要由外壳和心子及出线套管组成,外壳用薄钢板或不锈钢板焊接制成,盖上焊有出线套管,两侧壁上均焊有供安装,吊运的吊攀,心子由元件、绝缘件组成。元件有用聚丙烯薄膜为介质与铝箔(极板)卷制而成或用聚丙烯薄膜和电容器纸为介质与铝箔卷制而成。
2.高电压并联电容器的内部联接一般为单相形式,用户需要时可提供三相产品。
3.部分高压并联电容器内部每个元件串有内熔丝,能及时切除个别击穿的元件,保证电容器整体的正常运行。
4.部分高压并联电容器内部装有放电器件,可使电容器断开电源后的剩余电压在10min内由2Un降至75V以下。根据购买方需要,可使装置在更短时间内减至更低电压。
使用条件SERVICECONDITIONS
海拔高度不超过1000m,环境空气温度-40℃~ 40℃
安装场所无剧烈的机械振动、无有害气体及蒸汽、无导电性及爆炸性尘埃
连续运行电压1.0Un,长期过电压最高值不超过1.1Un
稳态过电流(包括谐波电流)不超过1.43In
最大允许容量不超过1.35Qn
高电压并联电容器主要应用于50HZ或60HZ交流电力系统以改善功率因数,产品性能负荷GB3983.2-89《高电压并联电容器》及国际标准IE60671-1.
RFM0.375-300-1S37510003004*84.93361533702M12292
RFM0.375-500-1S37510005006*94.44401704203M12423
RFM0.375-600-1S37510006006*113.24401704803M12534
RFM0.375-250-2.5S37525002504*28.3361232201M12145
RFM0.375-500-2.5S37525005004*56.63361233701M12246
RFM0.375-750-2.5S37525007506*56.63361533702M12247
RFM0.375-850-2.5S37525008506*64.23361534202M12328
RFM0.375-1000-2.5S375250010006*75.53361704502M16399
RFM0.375-260-4S37540002604*18.43361232201M121410
RFM0.375-360-4S37540003604*25.53361232201M121411
RFM0.375-720-4S37540007204*513361233701M162412
RFM0.375-320-8S37580003204*11.33361232201M121413
RFM0.375-500-1S37580008004*28.33361233701M162414
RFM0.5-500-1S50010005006*53.13361533702M122915
RFM0.5-1070-1S500100010708*85.24401704804M125416
RFM05-250-2.5S50025002504*15.93361232201M121417
RFM0.5-500-2.5S50025005004*31.83361233201M122418
RFM0.55-1000-2.5S550250010006*35.13361533702M122919
RFM0.75-750-0.5S7505007506*70.83361535002M124120
RFM0.75-1000-0.5S750500100010*56.64401704805M125521
RFM0.75-360-1S75010003604*25.53361232201M121422
RFM0.75-720-1S75010007204*513361233701M12242100433B
高压并联电容图片和格参考
高压并联电容器 高压并联电容器
高压并联电容器
高压并联电容全型号尺寸图
一 BAM1.05-30-1W 1.05 30 86.6 1(3) BAM1.05-50-1W 1.05 50 144.1 1(3) BAM1.05-60-1W 1.05 60 173.2 1(3) BAM1.05-100-1W 1.05 100 288.7 1(3) BAM3.15-100-1W 3.15 100 32.1 1(3) BAM3.15-200-1W 3.15 200 64.2 1(3) BAM6.3-12-1W 6.3 12 0.95 1(3) BAM6.3-14-1W 6.3 14 1.1 1(3) BAM6.3-16-1W 6.3 16 1.2 1(3) BAM6.3-18-1W 6.3 18 1.4 1(3) BAM6.3-30-1W 6.3 30 2.4 1(3) BAM6.3-40-1W 6.3 40 3.2 1(3)
全书共分7章,分别是:并联电容器原理及构造;高压并联电容器组设计;高压并联电容器的运行;高压并联电容器的维护检修;高压并联电容器组配套设备;并联电容器组保护;并联电容器组的操作过电压。
《高压并联电容器管理制度宣贯培训读本》可供电力企业从事高压并联电容器工作的工程技术人员及管理人员使用,也可供其他人员参考。
第一章 并联电容器原理及构造
第一节 电容器的发展概况
第二节 高压并联电容器的种类
第三节 电容器的基本原理
第四节 电容器的电场能
第五节 电力电容器的绝缘介质
第六节 电力电容器的结构
第二章 高压并联电容器组设计
第一节 并联电容器装置的设计
第二节 并联电容器额定电压的选择
第三节 集合式并联电容器
第四节 并联电容器装置质量控制
第三章 高压并联电容器的运行
第一节 新安装电容器装置设备验收
第二节 并联电容器的运行管理
第三节 运行电压异常对电容器的影响
第四节 电容器投入时的涌流
第五节 电容器运行中的过负荷能力
第六节 谐波对电容器的影响
第四章 高压并联电容器的维护检修
第一节 电容器的日常维护及安装
第二节 电容器的检修
第三节 并联电容器的老化与寿命
第四节 并联电容器的试验
第五章 高压并联电容器组配套设备
第一节 真空断路器
第二节 串联电抗器
第三节 氧化锌避雷器
第四节 熔断器及熔丝保护
第五节 放电线圈
第六章 并联电容器组保护
第一节 电容器组故障类型及保护配置
第二节 电容器组中性点不平衡保护
第三节 电容器组的电压保护
第四节 电容器组的其他保护
第五节 集合式并联电容器内部故障特点及保护方式
第七章 并联电容器组的操作过电压
第一节 电容器合闸过电压
第二节 电容器分闸过电压
第三节 电容器操作过电压的抑制
附录 并联电容器部分产品目录
参考文献2100433B