干粉灭火系统 powder extinguishing system,由干粉供应源通过输送管道连接到固定的喷嘴上,通过喷嘴喷放干粉的灭火系统。
中文名称 | 干粉灭火系统 | 外文名称 | powder extinguishing system |
---|---|---|---|
范 围 | 石油化工、油船、油库、加油站 | 软管长度 | 可达30-40 m |
干粉罐 | 中压容器,由罐体、安全阀、人孔 | 作 用 | 通过喷嘴喷放干粉的灭火系统。 |
ZFP型自动干粉灭火系统由启动装置(如:启动气瓶+拉杆机构)、氮气瓶组、减压阀、干粉罐、干粉枪、干粉炮、干粉喷头、电控柜、阀门和管系等零部件组成。一般为火灾自动探测系统与干粉灭火系统联动。
ZFP series DCP consists of starting device (Eg.:start cylinder + pull-rod mechanism), N2 cylinders, pressure reducing valve, powder tank, powder gun, automatic powder monitor, fixed powder nozzel, controller, valves, pipe lines and other accessories. In common use, ZFP series DCP is applied in using link with the fire-detecting system.
干粉罐是中压容器,由罐体、安全阀、人孔(装粉口)、进气口及出粉口等组成。
Powder Tank is a Middle-pressure vessel, consists of vessel, safety valve, manhole (powder intake hole), Nitrogen intake hole and powder discharge etc.
干粉炮是由耐压铜材和不锈钢制成,根据要求自动干粉炮(电动或液动)可在仰角40°俯角60°回转270°范围内工作;手动干粉炮可在仰角70°俯角60°回转360°范围内工作。
Powder monitor is fabricated by copper alloy and stainless steel, according to relative specification, the electric or hydraulic operated monitor can rotate between 40° to -60° in vertical direction, 270° in horizontal direction; the manual operated monitor can rotate between 70° to -60° in vertical direction, 360° in horizontal direction;
干粉枪与卷盘连在一起,卷盘中的软管长度可达30-40 m。
Powder gun is installed together with hose reel, the powder transport hose can have a max length: 30-40 m.
如果设备仅要求手动操作,则采用手动干粉炮、手动阀门和手动控制启动气瓶组件。
If only manual operation is needed, adopt a combination of manual dry chemical powder, manual valve and manual start cylinder.
系统工作原理是:利用氮气瓶组内的高压氮气经减压阀减压后,使氮气进入干粉罐,其中一部分被送到罐的底部,起到松散干粉灭火剂的作用。随着罐内压力的升高,使部分干粉灭火剂随氮气进入出粉管被送到干粉炮,干粉枪或干粉固定喷嘴的出口阀门处,当干粉炮、枪或干粉固定喷嘴的出口阀门处的压力到达一定值后(干粉罐上的压力表值达1.5~1.6MPa时),打开阀门(或者定压爆破膜片自动爆破),将压力能迅速转化为速度能,这样高速的气粉流便从干粉炮(或干粉枪,固定喷嘴)的喷嘴中喷出,射向火源,切割火焰,破坏燃烧链,起到迅速扑灭或抑制火灾的作用。
The principle of work for DCP system: Releasing the high pressured Nitrogen from Nitrogen Cylinder to Reduction Valve and decompresses the pressure to the work pressure, then transport them into Powder Tank, amount of them are transported to the bottom of the tank to relax the powder. Along with the tank's contenting pressure update, some powders are transfer to the discharge pipe and arrive at the valve bellowing the powder monitor / powder gun or powder nozzle along with the pressured Nitrogen, when the pressure in the valve arrives at the rated pressure (or the pressure gauge on the tank indicate 1.5~1.6MPa), open the valve (or the breakable diaphragm breaking auto.), then the pressure energy are translated to speed energy, high speed powder spray out from monitor (gun or nozzle ), shot at the fire, incise the flame, destroy the burning chain, then stifle the fire quickly.
ZFP型系列自动干粉灭火系统是石油化工、油船、油库、加油站、港口码头、机场、机库等工程的灭火系统的重要装备。干粉灭火系统是以氮气为动力,向干粉罐内提供压力,推动干粉罐内的干粉灭火剂,通过管路输送到干粉炮,干粉枪或固定喷嘴喷出,以达到扑救易燃、可燃液体,可燃气体和电气设备火灾的目的。
ZFP series Automatic Dry Chemical Powder Extinguish System (Short as: DCP) are important equipments for the fire-fighting in petrochemical industry, oil tanker, oil storage, gas station, dock and harbor, airport and hangar etc. ZFP series DCP is driven by high-pressure N2, then establishes pressure in the powder tank, press the chemical powder and force it through the pipelines to the powder monitor, powder gun or fixed powder nozzle, and by these equipments, spray the powder out on the flammable liquid, flammable gas or electric equipment fire to extinguish the fire.
山东-工业-干粉灭火系统是否需要系统调试答:需要系统调试的
超细干粉灭火剂自2001年由武汉绿色消防器材有限公司研发并送检合格后,2006年以前一直是执行企业标准,2005年由天津消防所组织,上海矣普托斯消防设备有限公司、武汉绿色消防器材有限公司参与编写了《超...
套灭火系统内的干粉型灭火器,然后换下主材。
ZFP型自动干粉灭火系统对A、B、C、D四类火灾都可使用,大量的还是用于B、C类火灾(应根据保护对象选用相应的干粉灭火剂)。其主要特点如下:灭火时间短、灭火效率高、对石油产品的灭火效果尤为显著;绝缘性好,可扑救带电设备的火灾,灭火后对设备污损较小;寒冷地区不需防冻,且可用于缺水地区;干粉灭火剂久贮不变质。
ZFP series DCP system can be used in A, B, C, D four kinds fire, the most common use is in B & C kind fire (according to different kind of fire choose the different type dry chemical powder for protection). Main futures bellowing: Short time for extinguishing, high extinguishing effective, outstanding effective on petrol product fire, best insulation, good effective on electric equipment fire, low pollution after extinguish, needless for frozen protect in cold weather, also can be used in water-lack area, best seal and storage for powder.
干粉灭火系统及灭火器.
一级消防工程师考点干粉灭火系统分类 干粉灭火系统是由干粉供应源通过输送管道连接到固定的喷嘴上, 通过喷嘴喷放干粉的 灭火系统。 干粉灭火系统分类 分类标 准 类别 描述 按灭火 方 全淹没式干 粉灭火系统 指将干粉灭火剂释放到整个防护区, 通过在防护区空间 建立起灭火浓度来实施灭火的系统形式。 该系统的特点是对 防护区提供整体保护, 适用于较小的封闭空间、 火灾燃烧表 面不宜确定且不会复燃的场合,如油泵房等类场合 式分类 局部应用式 干粉灭火系统 指通过喷嘴直接向火焰或燃烧表面喷射灭火剂实施灭 火的系统。当不宜在整个房间建立灭火浓度或仅保护某一局 部范围、 某一设备、 室外火灾危险场所等, 可选择应用式干 粉灭火系统, 例如用于保护甲、 乙、丙类液体的敝顶罐或槽, 不怕粉末污染的电气设备以及其他场所等 按设计 情 设计型干粉 灭火系统 指根据保护对象的具体情况, 通过设计计算确定的系统 形
超细干粉灭火系统分类的界定:
根据GB16668-2010标准,干粉灭火系统按干粉的驱动方式可分为:a)贮气瓶型干粉灭火系统、b)贮压型干粉灭火系统、c)燃气驱动型干粉灭火系统,而GB50347-2004及DB37/T1317-2009两个标准中,只有:全淹没灭火系统、局部应用灭火系统、预制灭火装置三种界定,标准中对预制灭火系统的规定过于简单,如GB50347-2004中规定:预制灭火系统应符合下列规定: 灭火剂存储量不得大于150kg. 管道长度不得大于20m. 工作压力不得大于2.5Mpa DB37/T1317-2009标准规定:预制灭火系统应符合下列规定: 灭火剂存储量不得大于150kg. 管道长度不得大于50m. 工作压力不得大于2.5Mpa 两个标准只是在管道长度上有所区别,并未列出预制灭火系统的型式,DB37/T1317-2009标准在条文解释中注明为:“预制灭火装置即在生产厂家按规定的型号预制的灭火装置,如柜式超细干粉灭火装置,该类灭火装置与管网灭火系统相比,充装的灭火剂量相对少,灭火剂输送的管道相对短,保护范围相也对小,因此本规范对该类灭火装置规格及应用范围作了规定。” 按上述内容,预制灭火系统的界定只是灭火剂量有了明确规定,如果按管道的长度来分析,贮压型灭火系统应该在预制灭火系统的范围,因为贮压型灭火系统没有后续的驱动压力,灭火剂输送管道不能太长,但由于GB16668-2010标准中并未对贮压型灭火系统的超细干粉灭火剂充装量作任何规定,据笔者所知,目前,市场上已经存在有贮压型干粉系统充装量超过150kg的规格,并且,如果单纯以贮压型来定论为预制灭火装置,也是不确切的,柜式超细干粉灭火装置虽然灭火剂充装量小,标准把其定为预制灭火装置,但柜式超细干粉灭火装置也有贮压型和贮气瓶型两个类别,这样一来,让设计人员很难判定到底哪种形式的灭火系统为预制灭火装置。 依笔者之见,贮压型干粉灭火系统由于驱动气体和超细干粉灭火剂贮存在同一容器内,不可能制作成庞大体积,虽然按照管网计算方式,其输送管道可能超过50米,灭火剂量也能达到500kg(甚至更大),但由于其后续喷射力不够,应该规定为灭火剂量充装小于300kg,并直接界定为预制灭火系统,这样有利于设计人员选型。
以上内容均根据学员实际工作中遇到的问题整理而成,供参考,如有问题请及时沟通、指正。
超细干粉灭火系统。以驱动方式分类为:贮气瓶型超细干粉灭火系统(型号为:ZFP100AC、ZFP300AC、ZFP400AC、ZFP500AC、ZFP750AC、ZFP1000AC、ZFP1500AC)、贮压型超细干粉灭火系统(ZFY25AC、ZFY50AC、ZFY200AC、ZFY100AC、ZFY50AC(II)、ZFY5AC(II)、充装的灭火剂类别又可分为:ABC超细干粉灭火系统、D类超细干粉灭火系统,以固定方式分类为:固定式超细干粉灭火系统、半固定式超细干粉灭火系统(如柜式超细干粉灭火装置)。
超细干粉灭火系统是由超细干粉供应源通过输送管道连接到固定的喷嘴上,再通过喷嘴喷放超细干粉灭火的系统。广泛用于生产车间、大型仓库、车库、机场飞机库等场所高效扑救A、B、C、D、E类火灾。